J. Kissel, J. Warner, E. Merilh I've updated the QUAD_MASTER.mdl, BSFM_MASTER.mdl, and HLTS_MASTER.mdl front-end library parts to obtain the changes Stuart has installed (see LLO aLOG 15437) in order complete ECRs E1400295 and E1400434, which have been tracked with II 969 -- "Changing Optical Lever DAQ Channels," and II 921 -- "Removal of old Guardian Parts," respectively, (governed by Work Permit #4932). This affects all core optics with optical levers, i.e. H1SUSPR3, H1SUSSR3, H1SUSBS, H1SUSITMX, H1SUSITMY, H1SUSETMX, H1SUSETMY. This should close out the above mentioned ECRs and Integration Issues. Thanks to Jim and Ed for their help. In doing so, we had to - svn up /opt/rtcds/userapps/release/sus/common/models/ - Request all affected SUS guardians to SAFE - Capture new safe.snaps for all affected SUS (not necessary, but seems to be good practice) - Request all affected SEI guardians to OFFLINE - Recompile the model / front-end code, make [h1suspr3, h1sussr3, h1susbs, h1susitmx, h1susitmy, h1susetmx, h1susetmy] - Reinstall the model / front-end code, make install-[h1suspr3, h1sussr3, h1susbs, h1susitmx, h1susitmy, h1susetmx, h1susetmy] - Restart the model / front-end code, ssh [h1sush2a, h1sush56, h1susb123, h1susex, h1susey] start[h1suspr3, h1sussr3, h1susbs, h1susitmx, h1susitmy, h1susetmx, h1susetmy] - Request all affected SUS guardians to ALIGNED - Request all affected SEI guardians to FULLY_ISOLATED / HIGH_ISOLATED* Bringing back up the SEI platforms was more challenging than expected, but I'll write a separate aLOG on that since it'll be focused on SEI issues.