david.barker@LIGO.ORG - posted 07:55, Wednesday 05 November 2014 (14861)
CDS model and DAQ restart report, Tuesday 4th November 2014

model restarts logged for Tue 04/Nov/2014
2014_11_04 09:13 h1suspr3
2014_11_04 09:18 h1susbs
2014_11_04 09:18 h1sussr3
2014_11_04 09:20 h1susitmx
2014_11_04 09:22 h1susitmy
2014_11_04 09:24 h1susetmx
2014_11_04 09:25 h1susetmy
2014_11_04 09:41 h1lsc

2014_11_04 09:46 h1broadcast0
2014_11_04 09:46 h1dc0
2014_11_04 09:46 h1fw0
2014_11_04 09:46 h1fw1
2014_11_04 09:46 h1nds0
2014_11_04 09:46 h1nds1

2014_11_04 10:34 h1calex
2014_11_04 10:35 h1caley
2014_11_04 11:12 h1iopoaf0
2014_11_04 11:12 h1pemcs
2014_11_04 11:14 h1oaf
2014_11_04 11:14 h1odcmaster
2014_11_04 11:14 h1tcscs

2014_11_04 12:36 h1broadcast0
2014_11_04 12:36 h1dc0
2014_11_04 12:36 h1fw0
2014_11_04 12:36 h1fw1
2014_11_04 12:36 h1nds0
2014_11_04 12:36 h1nds1

no unexpected restarts. Maintenance Day. Jeff SUS and LSC model work (with associated DAQ restart). Dave CAL work (with associated DAQ restart, plus latest Guardian and Beckhoff EDCU channels)