ISS maintanance

As the wandering laser intensity continues I intend to learn more about these systems. I can only report the findings and make the adjustments. ISS diffracted power is down to ~5% this morning. REFSIGNAL was at -2.04V as it was set by me yesterday. Today I have adjusted REFSIGNAL to -2.02V to bring the diff power to ~8.6%. Attached is a past 5 day trend. the spikes, i am told,  are likely caused by activations on MC2? (for example)

Non-image files attached to this report
Comments related to this report
edmond.merilh@LIGO.ORG - 10:33, Thursday 06 November 2014 (14891)

Here is the former plot put together with the PMC trans pwr plot as requested by P King.