Attached are the results from the first round of testing of this QUAD.  What we see:

1) Very poor coherence at low f which I had a hard time improving

2) Some cross coupling between T and R on the main chain

3) Some minor cross coupling between some P and L on the main chain

4) The 3rd L mode or 2nd P mode is split and the 2 are cross coupled on the reaction chain

Non-image files attached to this report
Comments related to this report
betsy.weaver@LIGO.ORG - 11:33, Friday 07 November 2014 (14913)

Attached are the plots of this QUAD compared to the data from the other 3 3IFO QUAD units.

Non-image files attached to this comment
betsy.weaver@LIGO.ORG - 12:33, Friday 07 November 2014 (14919)

Note, damped TFs and spectra to follow.