Displaying report 1-1 of 1.
Reports until 14:59, Monday 10 November 2014
H1 ISC
evan.hall@LIGO.ORG - posted 14:59, Monday 10 November 2014 - last comment - 16:58, Monday 10 November 2014(14952)
EY green WFS work

Nic, Evan

We went down to EY to see what was up with the green WFS on ISCTEY (D1400241). To start with, we decided to resteer the beams so that they are not clipping on any optics.

We also tightened down PD4, which had some issues with loose mounting.

Comments related to this report
nicolas.smith@LIGO.ORG - 16:40, Monday 10 November 2014 (14956)

Somehow, aligning the beam on the Green LSC PD gave us a factor of 10 more power.

Attached, one may see the change in power on the green refl PD at end Y. The first shows just a few hours from today, showing the change in power.

Also attached is 2 weeks of trends, to see if the PD was well aligned in the past, and it was just bad this morning. As far as I can tell, the power from this morning was a common number measured by this diode. There are also times with the power larger, but the value is not stable. I'm not sure if this is when the arm is aligned. I will check once we again align the arm. 

Images attached to this comment
nicolas.smith@LIGO.ORG - 16:58, Monday 10 November 2014 (14957)

The WFS PZT centering servos were measured and tuned up. All DsOF have UGFs that equal to roughly 10Hz.

Images attached to this comment
Displaying report 1-1 of 1.