corey.gray@LIGO.ORG - posted 08:11, Tuesday 11 November 2014 - last comment - 10:26, Tuesday 11 November 2014(14963)
PSL is showing NO power

The state of the PSL upon my arrival this morning was that it showed NO output power.

Comments related to this report
corey.gray@LIGO.ORG - 09:17, Tuesday 11 November 2014 (14966)

The power watchdog tripped. With the tutelage of Rick savage i was able to restart the frontend. Everything came back as normal except for the ISS loop that was acting erratically. It was discovered by Gabriele that the second ISS loop was still engaged and that was the cause for the unstableness. The output power monitor PD is currently reading 29.4W. ISS is reading ~6.8% dif power @ -2.11 refsignal.

edmond.merilh@LIGO.ORG - 10:26, Tuesday 11 November 2014 (14968)

The original log and first comment was entered by me. I used a browser window that was left by Corey from the day before.