The power watchdog tripped. With the tutelage of Rick savage i was able to restart the frontend. Everything came back as normal except for the ISS loop that was acting erratically. It was discovered by Gabriele that the second ISS loop was still engaged and that was the cause for the unstableness. The output power monitor PD is currently reading 29.4W. ISS is reading ~6.8% dif power @ -2.11 refsignal.
edmond.merilh@LIGO.ORG - 10:26, Tuesday 11 November 2014 (14968)
The power watchdog tripped. With the tutelage of Rick savage i was able to restart the frontend. Everything came back as normal except for the ISS loop that was acting erratically. It was discovered by Gabriele that the second ISS loop was still engaged and that was the cause for the unstableness. The output power monitor PD is currently reading 29.4W. ISS is reading ~6.8% dif power @ -2.11 refsignal.
The original log and first comment was entered by me. I used a browser window that was left by Corey from the day before.