J. Kissel, J. Garcia The Binary I/O medm screen was added to the FMY Overview medm and the names of the "T1", "T2", and "T3" strings changed to "F1","F2", and "F3" strings to denote the FMY "Face" OSEM configuration. Attached is a snapshot of the new screen accessible from the top row of the FMY Overview medm. This will allow the switching of the I/O chassis signal path and the actuation of the OSEMs. The ability to actuate on the OSEMs was confirmed with a simple sine wave drive via DTT and by offsetting the output drive values, monitored with dataviewer. The actual switch for allowing actuation via the test output filters is the channel 'H2:SUS-FMY_BIO_M1_CTRL' with a new value of "0xaaa". The channel 'H2:SUS-FMY_BIO_M2_CTRL' now has a value of "0xfff".