Displaying report 1-1 of 1.
Reports until 17:35, Monday 17 November 2014
H1 AOS
gabriele.vajente@LIGO.ORG - posted 17:35, Monday 17 November 2014 (15113)
Light reflected back by PRM - update

After the fix reported earlier, the contamination of ISS signals by the PRM reflection is smaller than before, but still not neglegible, see the attached plot (blue PRM misaligned, red PRM aligned).

We should investigate more to see if this residual noise is still entering from the same path or not. Maybe it would be a good idea to dump the beamp directly before the first mirror of the periscope.

Images attached to this report