H2SUSITMY Simulink Model + Medm Screens Updated
Similar to what I've done for the X1SUSQUAD's model yesterday, H2SUSITMY's model had to have some channels re-arranged given the new M0 / R0 OSEM arrangement shown in T1100327-v3 and D1001725-v7. This update is now complete for H2SUSITMY (only). 

In addition, I've brought the QUAD_MASTER.mdl library part up to the standard we'd finished with the triples at LLO a few weeks ago, in that the M0, L1 and L2 stages now use the SIXOSEM_F_STAGE_MASTER.adl, FOUROSEM_STAGE_MASTER.adl and FOUROSEM_STAGE_MASTER (respectively), and all stages use the sus-subsystem-wide-usable WATCHDOG.c instead of the quad-specific QUAD.c. Because their control schemes are unique to the QUAD, R0 and L3 do not have their own stage master, but are left as part of the overall QUAD_MASTER.mdl library part. Finally, the BIO interaction has been brought up to the "RCG2p3 Strategy" referenced in T1100507.