Displaying report 1-1 of 1.
Reports until 10:19, Friday 07 October 2011
H2 SEI
corey.gray@LIGO.ORG - posted 10:19, Friday 07 October 2011 - last comment - 14:12, Monday 10 October 2011(1515)
BSC8-ISI Cabling Work

(Corey, Filiberto, Hugh, Jim, Mitch, Vincent) 

****  This covers Testing & Installation of Cables for BSC8 which covered much of this week.  ****

Swapping Cables & Laying Them Out For Final Configuration

Other than the Capacitive Position Sensors, cabling for the BSC8-ISI had been Class-B.  This week we swapped out these cables for Class-A cables, and  positioned them on the ISI in a "final configuration".  Photographed cable layouts, and posted in ResourceSpace, here.  Below are the serial numbers and locations for all of the cables we installed this week.

Cable Serial Numbers

Drawing # (D11001__) S/N (S110____) LOCATION
_48 _4051 Corner1_Stage1_Horiz Actuator Extension
_48 _4050 Corner1_Stage1_Vert Actuator Extension
_48 _4057 Corner1_Stage2_Horiz Actuator Extension
_48 _4058 Corner1_Stage2_Vert Actuator Extension
_50 _5188 Corner1_Stage1_Horiz Actuator
_50 _5187 Corner1_Stage1_Vert Actuator
_51 _4085 Corner1_Stage2_Horiz Actuator
_51 _4084 Corner1_Stage2_Vert Actuator
_52 _5193 Corner1_Trillium
_53 _4556 Corner1_GS13 Extension
_53 _4557 Corner1_L4C Extension
_54 _4256 Corner1_L4C
_55 _4120 Corner1_GS13
_48 _4056 Corner2_Stage1_Horiz Actuator Extension
_48 _4049 Corner2_Stage1_Vert Actuator Extension
_48 _4047 Corner2_Stage2_Horiz Actuator Extension
_48 _4048 Corner2_Stage2_Vert Actuator Extension
_50 _5189 Corner2_Stage1_Horiz Actuator
_50 _5186 Corner2_Stage1_Vert Actuator
_51 _4086 Corner2_Stage2_Horiz Actuator
_51 _4094 Corner2_Stage2_Vert Actuator
_52 _5192 Corner2_Trillium
_53 _4560 Corner2_GS13 Extension
_53 _4561 Corner2_L4C Extension
_54 _4257 Corner2_L4C
_55 _4122 Corner2_GS13
_48 _4055 Corner3_Stage1_Horiz Actuator Extension
_48 _4054 Corner3_Stage1_Vert Actuator Extension
_48 _4053 Corner3_Stage2_Horiz Actuator Extension
_48 _4052 Corner3_Stage2_Vert Actuator Extension
_50 _5191 Corner3_Stage1_Horiz Actuator
_50 _5190 Corner3_Stage1_Vert Actuator
_51 _4082 Corner3_Stage2_Horiz Actuator
_51 _4083 Corner3_Stage2_Vert Actuator
_52 _5194 Corner3_Trillium
_53 _4558 Corner3_GS13 Extension
_53 _4559 Corner3_L4C Extension
_54 _4258 Corner3_L4C
_55 _4121 Corner3_GS13

SUS Viton Cable Clamps Installed

Swapped out Peek cable clamps with newer Viton Cabl Clamps for the SUS cabling strung on the side (at Corner3) of the ISI (we did NOT address any clamps on the Optical Table. (photo of Jim installing a clamp is attached)

Testing Seismometer Cables

Before connecting cables to the Interface Feedthrus and Powering ON the seismometers, we used our Emulator box to test out the cables for the L4C's and GS13's.  (We were not able to test out the Trillium Cables; we tried the STS2 Emulator, but this did not work for us.)

Balancing Stage 2 & Capacitive Position Sensor (CPS) Issues

On Wed night we made an attempt at checking/balancing the ISI because the SUS group wanted to run measurements on a floating ISI.  We were surprised at how much Stage2 was off.  It took a while, but we were able to get all the Vert CPS under 0.5V. 

After this, we locked up Stage2, and unlocked Stage1 to begin balancing, but then we noticed we had a railed (+13V) V3 CPS.  In all liklihood, we are going to have to swap this CPS and board out (we checked it and its cabling several times to no avail).  

Images attached to this report
Comments related to this report
corey.gray@LIGO.ORG - 14:12, Monday 10 October 2011 (1531)

Change to Cabling Table Above

After routing cables last week, we tested Actuator cables and it was noticed (2) Actuators were wired up wrong (Corner3's Horiz & Vert Fine Actuators were basically switched).  The cables were then switched. 

On Friday afternoon, I did one more check of all of our cables to confirm everything matched the documentation, and sure enough I saw that the (2) actuators we switched were physically cabled to the wrong actuators! 

This morning, we checked the cabling here, and the problem was traced to the Position Sensors (what we use to look at what the Actuators do).  The Horiz & Vert Fine Capacitive Position Sensors (CPS's) were the culprits (a Horiz cable was connected to a Vertical Sensor, and vice versa).  These CPS's were switched to a correct configuration, and the Actuators were also switched.....all this switching occurred at the Interface Feedthru.

So, to be thorough, here is the correct cabling layout for the Fine Actuators at Corner 3 (:

Drawing # (D11001__) S/N (S110____) LOCATION
_48 _4052 Corner3_Stage2_Horiz Actuator Extension
_48 _4053 Corner3_Stage2_Vert Actuator Extension
_51 _4083 Corner3_Stage2_Horiz Actuator Extension
_51 _4082 Corner3_Stage2_Vert Actuator Extension
Displaying report 1-1 of 1.