Reports until 11:30, Monday 24 November 2014
H1 ISC (ISC, SUS)
stefan.ballmer@LIGO.ORG - posted 11:30, Monday 24 November 2014 - last comment - 11:55, Monday 24 November 2014(15260)
Dealing with ETMX L1 L2P trouble
Since the ETMX L1 L2P filters gave us a unstable x-arm lock once ALS-DIFF was engaged, we switched to a DC-only strategy:
 - Instead of the the L2P/L2Y filters we simply used flat gains, and tuned them at 0.1 Hz:
     Pitch: -60dB (FM10) * gain of  5.3
     Yaw:   -60dB (FM10) * gain of -0.7

 - We also tweaked the ESD L2P/L2Y's at 2Hz:
     Pitch: gain of 0.021
     Yaw:   gain of 0.007

 - This left some AC pitch fluctuations on ETMX. The OPLEV took care of that. We now have a stable ALS DIFF and COMM running in this configuration.
Comments related to this report
alexan.staley@LIGO.ORG - 11:55, Monday 24 November 2014 (15261)

For reference:

The previous ETMX L1 filters were as follows: L2Y gain of 0. L2P FM1, FM2 ON with gain of -1.0. Nothing had been installed in L3.

 