Displaying report 1-1 of 1.
Reports until 11:30, Tuesday 11 October 2011
H2 SEI
corey.gray@LIGO.ORG - posted 11:30, Tuesday 11 October 2011 (1527)
Capacitive Positioin Sensor (CPS) Swapped For BSC8-ISI

(Corey, Jim, Vincent)

V3 CPS Swap

At Corner3, we had a broken  Coarse (Stage0-1) Vertical (V3) CPS;  the serial numbers for the bad CPS/board are:  12865 & 12337.  The Sensor was removed from the ISI, and its board was pulled out of its mini-rack.

The new Sensor was installed/aligned, its new board was installed in the rack, and then the gap was set for this Sensor.  Here are the serial numbers for our new V3 CPS:

S/N:  12898(probe) & 12416(guage/board) 

PS:  Vincent's informed me, may have yet another bad CPS, and yes, it's at Corner3 again (more to come later).