Displaying report 1-1 of 1.
Reports until 16:13, Saturday 01 November 2014
H1 SEI (SEI)
hugo.paris@LIGO.ORG - posted 16:13, Saturday 01 November 2014 - last comment - 16:14, Tuesday 25 November 2014(14794)
SEI Test Configuration Switching Scripts

A set of scripts was created last week to allow commissioners to switch SEI platforms to SEI’s preferred testing configuration at the end of their shift.

 

The scripts are very simple for now: 

Those new scripts were put in the svn so they can be remotely adjusted, and improved (made more generic, make classes/methods, etc…):
/ligo/svncommon/SeiSVN/seismic/BSC-ISI/H1/Common/Misc/Test_Configuration_Scripts/

To run those scripts:
$ cd /ligo/svncommon/SeiSVN/
$ python Switch_To_Test.py (at the end of the commissioning shift)
$ python Switch_To_Comm.py (when commissioning resumes)

Kiwamu used those scripts at the end of his shift on 10/28/14. JimW and I added the senscor switching capability on 10/29/14, which does not change the way to run the scripts.

Comments related to this report
jim.warner@LIGO.ORG - 16:14, Tuesday 25 November 2014 (15294)

These scripts are now executable. They are run by navigating to the folder and typing ./Switch_To_Comm.py or ./Switch_To_Test.py . They currently control HEPI Z and ISI X sensor correction for the X arm BSC's.

Displaying report 1-1 of 1.