Since our calibration of the CARM offset in physical units is not very accurate, I post here a couple of plots with powers vs TR_CARM_OFFSET (sqrt(TX + TY) = -TR_CARM_OFFSET). The highest power build up we reached so far had TR_CARM_OFFSET = -15 (see first plot, arm power = 115 x single arm, as measured by TR_Y_QPD_B_SUM, entry 15323 ); in this state the BS correction signal became very large and we unlocked in ~ 1 min. Even if we didn't stay long on the previous state (TR_CARM_OFFSET = -12, arm power = 74 x single arm), we didn't notice any instability there; so I think it is fair to say that TR_CARM_OFFSET = -12 is the highest stable state we reached. On Saturday , Stefan left the IFO locked with TR_CARM_OFFSET = -8 (arm power = 32 s single arm, Guardian state TR_QPD_TRANSITION). It stayed locked for about 1.5 h! (second plot). The current last step of the Guardian (which has been failing on Saturday) goes directly from -8 to -15 (corresponding to the state CARM_20PM). We will stop around -12 next time.