As requested by Paul, I had a look at some signals of the DRMI to see how much we gained in terms of the recycling gains by the recent TCSX engagement.

In brief, POP_RF18 increased by 8% and ASAIR_RF90 increased by 19% which is good. Naively speaking, the recycling gain for the 9 MHz SB increased by the same factor of 8 % by engaging TCSX. Also, note that the 45 MHz SB used to have a recycling gain of 21 before we started the unclipping effort (see alog 14532).

Below shows a table for side-by-side comparison. Note that the TCSed data is the ones from this after noon, at which point the ASC loop was not optimum for SRC.

 

  with TCSX (2014-12-02 22:30:14 UTC) in cnts without TCSX  (2014-11-24 2:44:01 UTC) in cnts  ratio (with/without)
POPAIR_A_LF  1100 1000 15%
POPAIR_B_LF 600 570 9 %
POPAIR_B_RF18_I 370 355 8 %
POPAIR_B_RF90_I 115 100 20 %
ASAIR_A_LF 9700 9400 7 %
ASAIR_B_LF 3300 3100 10 %
ASAIR_B_RF90_I 7200 6300 19 %
IMC_MC2_TRANS_SUM 777 811 -