Yesterday, we ran into issues with 2 of the 4 FMy Structure Stays for BSC8, namely that they were too long and could not mate correctly. With a Worden-waiver we cut down the tips of the D090002 pins by 1/4". They were wrapped in foil and ameristat with only the tip exposed during the modification, then they were recleaned and are in an airbake oven for 24 hours. The other 2 Stays were fit checked and mate properly. Kurt from CIT is visiting and found the problem in the SW model, so is updating drawings for the future units not yet procured.