I did this back 7 February, the numbers still look like they work well.
See the attached where I measure the tilt with the previous values and bracketed values around the good number. The blue traces are the original values and the green and red traces are with the vlues offset a bit. Still looks like the old values are the best. The first attachment is the inline measurements (drive Y) with the second attachment showing the croosline measurement (drive X.)