Displaying report 1-1 of 1.
Reports until 09:38, Tuesday 16 December 2014
H1 ISC
stefan.ballmer@LIGO.ORG - posted 09:38, Tuesday 16 December 2014 - last comment - 09:44, Tuesday 16 December 2014(15643)
9h lock of DRMI
I left the DRMI running last night with the SRC WFS and pointing loop running. We got a 9h lock out of it. But we still have to track down some drift - most likely the recycling cavity, because both 18 and 90 buildups are affected.

Start: 2014/12/16 06:04 UTC
Stop:  2014/12/16 15:41 UTC
Images attached to this report
Comments related to this report
sheila.dwyer@LIGO.ORG - 09:44, Tuesday 16 December 2014 (15644)

The drift of PR3 yaw OpLev seems to be a likely suspect for the drift in the DRMI build up, the same trend shows up in POP_B_YAW, so this might be a good signal to use to stabilize the PRC axis. 

Images attached to this comment
Displaying report 1-1 of 1.