Tonight we copied the BS OPLEV filters to the BS M2 LOCK pitch and yaw filters, and modified them slightly to get some moderate DC gain on top of a significant suppression at the optics resonances.
 - The modification we made is
   PIT and YAW: FM1: zpk([0],[100],1,"n") was replaced with zpk([0.1;0.1],[4000;100],0.2,"n") . Together with the WFS filter bank (a simple 1/f integrator) this results in very weak DC feed-back.
   PIT: We added a 1.2Hz resonance peak compensation and a p0.1:z1.5 low frequency boost to FM10:
      zpk([0.02+i*1.2;0.02-i*1.2],[0.200028+i*1.18338;0.200028-i*1.18338],1,"n")* zpk([1.5],[0.1],15,"n")
   The results in a reasonable secondary UGF crossing.

Pitch was tested, and resulted in a unconditionally stable loop.
Yaw wasn't tested yet. A snapshot of the engaged filters is attached.
Images attached to this report
Comments related to this report
stefan.ballmer@LIGO.ORG - 23:56, Tuesday 16 December 2014 (15664)
Also, from this morning's lock, here are some WFS signals that show clearly what is running away.

REFL_B_RF9_I seems to be the prime candidate.