The Ops Overview screen that shows the graphic representation of the IFO (OPS_OVERVIEW_CUSTOM.adl) had been previously unable to report individual suspension stage watchdog trips. According to the models, the discreet watchdog stages are "ANDED" into an EPICS channel called $(IFO):SUS-$(LOC)_DACKILL_TRIG_STATE which was the only conditional channel included for the Visibility Calculation in MEDM. This channel will never show it's alarm state unless all upstream watchdogs have been tripped therefore making said "trips" invisible in this overview, which has become a popular one with operators and others as well (imo). Discreet watchdog channels have been added and tested for BS and all Quad suspensions. This overview screen can now be relied on for accurate reporting on the status of any suspension watchdog trips.
TMSs and everything down the output arm has been added to his list, also.
All suspensions have been covered at this point. Please let me know if anyone experiences false reporting of status of suspensions in this view.