Dan, Fil, Thomas
We made a quick modification to the ASC-AS_C transimpedance board today, so that the HAM6 fast shutter threshold can be set for 1W of light into the chamber. The modification was a swap of R23, from 1.24k ohm to 422 ohm. This changes the gain on the SUM_OUT channel on the back of the chassis, that's used for the fast shutter logic.
ASC-AS_C gets 2.5% of the light into HAM6, so we'd like to set the threshold at 25mW. The input to the shutter controller rails at 2V. The QPD transimpedance is 1000 ohms, the quantum efficiency is probably about 80%, and the new resistor changes the final gain stage to 422/4.99k = 0.0845. So, the correct shutter threshold is 0.025*1000*0.8*0.0845 = 1.7 volts.
This modification only affects the signal path to the shutter controller; it doesn't change the signal path that is acquired by the ASC front end. So the ASC-AS_C sum that you see on the MEDM screen hasn't changed. (The input to the HAM6 shutter controller is recorded by the channel H1:SYS-MOTION_C_SHUTTER_G_TRIGGER_VOLTS.)