Displaying report 1-1 of 1.
Reports until 10:17, Thursday 26 August 2010
H2 General
james.batch@LIGO.ORG - posted 10:17, Thursday 26 August 2010 (158)
Awgstream, awgstream.m, and related files working on Seismic test stand.
I have installed a 32-bit version of awgstream, multiawgstream, and awgexc_run at /opt/apps/awgstream on seiteststand.  I also compiled awgexc_conf.c using mex.  

Modified ~controls/.bashrc to include paths /opt/apps/awgstream/bin and /opt/apps/awgstream/matlab_tools in $PATH.  

Time is now the same on workstation and seiteststand, so awgstream and dtt apps can be used on workstation again.  

Modified awgstream.m to include path to awgexc_run, this needs to be changed to get the path without hard coding!!!

Tested awgstream as standalone executable, and matlab script that uses awgstream.m, awgexc_run, and so on.  Did not verify that signals are actually injected and viewable with dataviewer, but no errors were reported.
Displaying report 1-1 of 1.