Converting contrast defect to ITM RoC change (diopter change)
The following elog is in support of Evan's upcoming elog on last nights TCS transient (turning off TCS)

Bottom line:

The contrast defect (CD) can be modeled as

CD = CD_0 + pi^2/8 * D^2*w^4/lambda^2 

where:
CD    : contrast defect
CD_0  : residual contrast defect, not due to ITM RoC mismatch
D     : Diopter change in (one) ITM, double pass, i.e. D=2*( 1/R_new - 1/R_old )
w     : beam spot radius on the ITM, nominally 53mm
lambda: wave length = 1.064e-6m 

Derivation: 

- incident beam:            |Psi> =  N exp(-r^2/w^2)
- ITMX reflection operator: exp(i*k*D*r^2/2)
- ITMY reflection operator: 1
- reflected field:          |r> = |Psi> * exp(i*k*D*r^2/4) *   cos(k*D*r^2/4)
- dark port field:          |t> = |Psi> * exp(i*k*D*r^2/4) * i sin(k*D*r^2/4)

- Power in dark port due to RoC mismatch:
    = k^2*D^2*w^4/32 = pi^2/8 * D^2*w^4/lambda^2 
  The bottom line formula for contrast defect follows from this.

Some other useful expressions:
- Power reflected from the Michelson:
    = 1 -  = 1 - pi^2/8 * D^2*w^4/lambda^2 
  Note that this power will be in a different mode, so the mode matching into the recycling cavity is expected to change.

And for reference, some Gaussian integrals:
   h_n := 
   h_n = n/4 w^2 h_(n-2)
   h_0 = 1
   h_2 = 1/2 w^2   
   h_4 = 1/2 w^4   
   h_6 = 3/4 w^6   
   h_8 = 3/2 w^8   


 
  
Comments related to this report
evan.hall@LIGO.ORG - 16:34, Tuesday 23 December 2014 (15815)

Stefan, Evan

Since we turned off the TCS last night and left PRMI locked on carrier, we have roughly 8 hours of good data that tells us the (1) the contrast defect and (2) the behavior of the ITM thermal lens as a function of time. To extract these quantities, we did the following:

  • We extrated minute trends of LSC-POP_A_LF_OUT, LSC-REFL_A_LF_OUT, and LSC-ASAIR_A_LF_OUT from last night.
  • We calibrated POP_A power to PRC power as follows:
    • FM10 already calibrates the POP_A counts into microwatts of power incident on the PD.
    • In Kiwamu's recycling gain measurement (LHO#15793), he misaligned PRM and locked MICH on a dark fringe. There was 7.2 μW on POP_A. Assuming a PSL power of 10.7 W (measured today), an IMC transmission of 83 % (LHO#9954), and a PRM transmission of 3.0 % (galaxy), this means there was 260 mW of power in the PRC.
    • The calibration PRC / POP_A is therefore 3.7×104 W/W.
  • We calibrated ASAIR_A power to SRC power as follows. Note that what I call "SRC power" is power leaving the BS going toward SRM (this is to distinguish it from "AS power" seen after the SRM).
    • ASAIR_A is already calibrated into microwatts of power incident on the PD.
    • In Stefan's contrast defect measurement (LHO#15332), he found the maximum SRC power from the free-swinging michelson was 1890 ct on ASAIR_B (not A). Today I measured the calibration to A is ASAIR_A / ASAIR_B = 3.52 ct/ct. The maximum SRC power from the free-swinging Michelson I take to be 10.7 W × 0.83 × 0.03 × 0.986 (this last number is the ITM reflectivity).
    • The calibration SRC / ASAIR_A is therefore 39 W/W.
  • We calibrated REFL_A to REFL (i.e., the power heading from the PRM to IM4) as follows:
    • FM10 already calibrates the REFL_A counts into milliwatts of power incident on the PD.
    • In yesterday's RFAM measurement (LHO#15781), we measured 81 mW on REFL_A with the PRM aligned and the ITMs misaligned. The REFL power I take to be 10.7 W × 0.83 × 0.97.
    • The calibration REFL / REFL_A is therefore 106 W/W.
  • It can be shown that the ratio PSRC / PPRC = TM RI, where TM is the carrier power transmissivity of the Michelson, and RI is the power reflectivity of each ITM. I assume RI = 0.986. Therefore, we can solve for TM as a function of time given the calibrated power measurements. This is given in the upper plot of the attachment. From last night's data alone, the starting value of TM is 1.115×10−3. However, Daniel has previously corrected the contrast defect for the presence of the 45 MHz sidebands (LHO#15432), finding a defect of 0.99×10−3. In the plot, I have rescaled TM by 0.99 / 1.115 to reflect this.
  • To convert ths into a change into diopters according to Stefan's formula, we need to know the "best" contrast defect achievable (i.e., the residual defect assuming no RoC mismatch). Stefan's measurement (LHO#15332) showed a minimum in ASAIR_B of (−0.2 + 1.78) ct with the Michelson locked on a dark fringe. According to Daniel's analysis, 0.17 ct of this is due to the 45 MHz sideband. So the net minimum is 1.41 ct. With a bright fringe power of 1890 ct, I take the "best" contrast defect to be 8×10−4.
  • By using this "best" defect and Stefan's formula above, we compute change in the ITM thermal lens (in diopters) as a function of time. This is given in the lower plot of the attachment.

In principle, we can also use the above data to extract the mode-matching into the PRMI as a function of time. Perhaps we will pursue this later.