Measured pump currents for different output power levels at the individual fiberbundle tip for the high power oscillator of the PSL.
The output power was measured with a thermopile 300 W external OEM Ophir power meter.
| output power at finberbundle tip / W | pump current FB 1 / A | pump current FB 2 / A | pump current FB 3 / A | pump current FB 4 / A |
| 10 | 11.1 | 11.4 | 11.4 | 11.4 |
| 20 | 12.8 | 13.0 | 13.1 | 13.0 |
| 30 | 14.5 | 14.6 | 14.7 | 14.7 |
| 40 | 16.2 | 16.2 | 16.3 | 16.3 |
| 50 | 17.9 | 17.8 | 17.9 | 18.0 |
| 60 | 19.6 | 19.4 | 19.6 | 19.6 |
| 70 | 21.3 | 21.0 | 21.2 | 21.2 |
| 80 | 23.0 | 22.6 | 22.8 | 22.9 |
| 90 | 24.7 | 24.2 | 24.4 | 24.5 |
| 100 | 26.4 | 25.8 | 26.1 | 26.2 |
| 110 | 28.1 | 27.4 | 27.7 | 27.8 |
| 120 | 29.8 | 29.0 | 29.3 | 29.4 |
| 130 | 31.5 | 30.6 | 30.9 | 31.1 |
| 140 | 33.2 | 32.2 | 32.6 | 32.7 |
| 150 | 34.9 | 33.7 | 34.2 | 34.4 |
| 160 | 36.6 | 35.3 | 35.8 | 36.0 |
| 170 | 38.2 | 36.9 | 37.4 | 37.6 |
| 180 | 39.9 | 38.5 | 39.1 | 39.3 |
| 190 | 41.6 | 40.1 | 40.7 | 40.9 |
| 200 | 43.3 | 41.7 | 42.3 | 42.6 |
| 210 | 45.0 | 43.3 | 43.9 | 44.2 |
| 220 | 46.7 | 44.9 | 45.6 | 45.8 |
| 230 | 48.4 | 46.5 | 47.2 | 47.5 |
| 240 | 50.1 | 48.1 | 48.8 | 49.1 |
| 250 | 51.8 | 49.7 | 50.4 | 50.8 |
| 260 | 53.5 | 51.3 | 52.1 | 52.4 |
| 270 | 55.2 | 52.9 | 53.7 | 54.0 |
| 280 | 56.9 | 54.5 | 55.3 | 55.7 |
| 290 | 58.6 | 56.1 | 56.9 | 57.3 |
| 300 | 60.3 | 57.7 | 58.6 | 59.0 |