Reports until 16:18, Wednesday 07 January 2015
H1 SEI
jim.warner@LIGO.ORG - posted 16:18, Wednesday 07 January 2015 - last comment - 16:30, Wednesday 07 January 2015(15927)
More HAM3 sensor correction measurements

I repeated the measurement from alog 15783, just checking coherence between HAMs 2&3 after we changed HAM3 to look at the right seismometer. Nothing obvious, but I found something interesting. The FIR_IN signals should all be the exactly same at this point, and so should be 100% coherent, between the chambers. The Z signal is not, but the difference is only below 50 mhz, at around .6hz the coherence is almost 100% again. Attached plot shows measurement from the middle of last ni.

Images attached to this report
Comments related to this report
jim.warner@LIGO.ORG - 16:30, Wednesday 07 January 2015 (15929)

Sensor correction is off on HAMs 2&3, I will leave it off on these chambers overnight. I'm also switching the cables on the AA chassis at the rack for STS-A. Will swap back tomorrow morning.