Schedule for BSC09 "Abbreviated Vent & Closure": Earth Quake Stop Adjustment of EX Test Mass, January 7-8, 2015
Approved work to be done:
-
Assessment of earth quake stops gaps for the test mass
-
Set lower EQ stops gaps to ~1.5 mm
Wednesday, Jan. 7
-
Turnoff EX BRS (Seismic Beam Balance)
-
Cleaning of BSC9
-
Verify or transition to “Laser Safe”
-
Move Clean Room (CR) into position for BSC9, check rooftop of Clean Room and attach sock, verify fans are working
-
Turn on purge air for BSC9
-
Verify supplies: Green Lantern, Flashlights, ion gun, etc. and make sure CR supplies are in place (gowns, change room, ...)
-
Dust Monitors - verify operation and take readings for before and after entry
-
Verify safe.snap files to save settings
-
Follow M1300464-v4, "Procedure for preparing aLIGO IFO for pumpdown", Turn off high voltage
-
Review and follow E1201035, "aLIGO Chamber Entry & Exit Procedures" checklist as annotated by Calum and Dennis for abbreviated entry
-
Review and follow M1100068-v1, "Hanford Checklist - BSC Door Removal", Review door removal procedure with crew
-
Start vent on BSC9
Thursday, Jan. 8
-
Remove door
-
Document entrance
-
Enter , assess quality of HR surface of ETMX with green flashlight
-
Adjust EQ stops gaps.
-
Verify optic, its suspension, and the reaction chain are free
-
Assuming all goes well, obtain approval and signatures for volume closure, LHO (E1400474-v1).
-
Obtain signoff signatures for chamber closure
-
Notify door crew to hang door
-
Verify readiness to pump down, follow M1300464-v4, "Procedure for preparing aLIGO IFO for pumpdown". Confirm all high voltages are off.
-
Notify Vacuum crew of readiness to start pumps
The last step is at the time and discretion of the Vacuum crew.