I wrote a script which compares a target's autoBurt.req file against its safe.snap file. This is a channel list check, verifying that the safe.snap has no more and no less channels compared to autoBurt.req. I am not checking channel values or channel read-only-status.
I ran the script on all the H1 models (100 of them). For models I manage (IOP and PEM) I fixed any mismatches. For any system which was missing a safe.snap, I created one by snapshotting the system.
The end result is that all safe.snaps are concurrent with the exception of:
certain SUS safe.snaps still retain the GUARD channels which were removed this Tuesday, Jeff K is going to resnap these this weekend
h1pslfss.snap is missing some DINCO channels, I'l work with PSL to resolve this
The psl fss fix was trivial, I have added the missing channel to h1pslfss_safe.snap by hand and committed to svn.