Reports until 17:17, Friday 09 January 2015
H1 CDS
david.barker@LIGO.ORG - posted 17:17, Friday 09 January 2015 - last comment - 17:25, Friday 09 January 2015(15978)
Checked safe.snap files as preparation for RCG2.9 upgrade

I wrote a script which compares a target's autoBurt.req file against its safe.snap file. This is a channel list check, verifying that the safe.snap has no more and no less channels compared to autoBurt.req. I am not checking channel values or channel read-only-status.

I ran the script on all the H1 models (100 of them). For models I manage (IOP and PEM) I fixed any mismatches.  For any system which was missing a safe.snap, I created one by snapshotting the system.

The end result is that all safe.snaps are concurrent with the exception of:

certain SUS safe.snaps still retain the GUARD channels which were removed this Tuesday, Jeff K is going to resnap these this weekend

h1pslfss.snap is missing some DINCO channels, I'l work with PSL to resolve this

Comments related to this report
david.barker@LIGO.ORG - 17:25, Friday 09 January 2015 (15982)

The psl fss fix was trivial, I have added the missing channel to h1pslfss_safe.snap by hand and committed to svn.