After Kyle finished active pumping on BSC9 for today, I took V and P TFs on the main chain of ETMx. The pressure has come down to 11 Torr, and the TFs look healthy. Recall, previously this supension started rubbing around ~400 Torr so we should be in pretty good shape, finally. We'll take final TFs on Monday, but this looks very good. Attached is just the Vertical TF, but the Pitch looks well matched to the model as well, and can be found in the appropriate svncommon/Sus... directory on CDS for further weekend scrutiny if wanted. (Not committed to svn yet however.) I also looked at the reaction chain vertical DOF and it's TF looks healthy still too.