J. Kissel I've caputured and committed new safe.snap files in order to capture the updated ODC bitmasks (see LHO aLOG 15951), as well as to remove old Guardian variables that are no longer in the autoburt.req file as of the removal of the guardian block from all models. A full list of those models' snap files that have been captured is shown below. Once captured, I've made sure that the alignment offsets and ASC loops have been restored. Note that some suspensions have integrators in the top stage P and Y LOCK filters, which have stored values in them (i.e. PRM, PR3, SRM, and SR3, BS, and ITMs). In order to capture the safe, I've turned off the outputs to these filters. However, again, once captured I've restored them and ensure the same outputs. h1susim h1sushtts h1susmc1 h1susmc2 h1susmc3 h1susprm h1suspr2 h1suspr3 h1sussrm h1sussr2 h1sussr3 h1susbs h1susitmx h1susitmy h1susetmx h1susetmy h1sustmsx h1sustmsy