DRMI ASC

Alexa, Evan, Sheila

We have a DRMI ASC cnfiguration in the guardian that seems good enough for now.  We have PRC2 (REFLB 9I to PR3), SRC1 (combination of AS 36 WFS to SR3),  SRC2 (combination of AS_C to SRM and SR2) with low bandwidth, and MICH (AS A 36 combination) to BS, oplev damping off. 

We have also edited the offloading in the guardian, so that we have a 20 second ramp time and we leave the loops running.  This works now.  

Comments related to this report
alexan.staley@LIGO.ORG - 17:21, Monday 19 January 2015 (16144)

Just to clarify, the BS IS running at high BW, unlike the rest of the loops.