Pulled ETMX photodiode amplifier chassis from EX. Keita reported voltage outputs seemed to be reversed (negative output). Found the wiring for the outputs of the amplifier box wired wrong. Corrected wiring and placed unit back in rack. Patrick had to restart the Beckhoff computer for EX. D1301017 SN S1400075
ETMX Baffle PDs now output positive voltage.
Gains were set to 0dB instead of 60.
Nominal currents for these (H1:AOS-ETMX_BAFFLEPD_1_NOMINAL and H1:AOS-ETMX_BAFFLEPD_4_NOMINAL) were set to 0.1mA instead of 0.
"powerOk" for ITMX in ditherAlign.py was set to 0.2 instead of 0.4.
After these changes the ditherAlign.py works for ITMX.