model restarts logged for Tue 20/Jan/2015
2015_01_20 00:05 h1fw0
2015_01_20 04:07 h1fw0
2015_01_20 10:29 h1iopsusex
2015_01_20 10:30 h1iopsusex
2015_01_20 10:31 h1susetmx
2015_01_20 10:31 h1sustmsx
2015_01_20 10:32 h1susetmx
2015_01_20 10:35 h1iopsusex
2015_01_20 10:35 h1susetmx
2015_01_20 10:37 h1sustmsx
2015_01_20 10:44 h1susetmx
2015_01_20 10:51 h1iopsusey
2015_01_20 10:51 h1susetmy
2015_01_20 10:51 h1sustmsy
2015_01_20 11:31 h1hpiham2
2015_01_20 11:31 h1hpiham3
2015_01_20 11:31 h1iopseih23
2015_01_20 11:31 h1isiham2
2015_01_20 11:32 h1hpiham2
2015_01_20 11:32 h1hpiham3
2015_01_20 11:32 h1iopseih23
2015_01_20 11:32 h1isiham2
2015_01_20 11:32 h1isiham3
2015_01_20 11:58 h1fw0
2015_01_20 11:58 h1nds0
2015_01_20 12:49 h1fw1
2015_01_20 12:49 h1nds1
2015_01_20 12:57 h1broadcast0
2015_01_20 12:57 h1dc0
2015_01_20 12:57 h1fw0
2015_01_20 12:57 h1fw1
2015_01_20 12:57 h1nds0
2015_01_20 12:57 h1nds1
maintance day preceded with two unexpected restarts. Restart tests on SUS ETMs. Power cycle of h1seih23 for noise hunting. Power cycle of DAQ solaris boxes, followed by DAQ restart for new slow controls ini files. Conlog frequently changing channels report attached.