Displaying report 1-1 of 1.
Reports until 13:07, Wednesday 21 January 2015
H1 SEI (SEI)
sebastien.biscans@LIGO.ORG - posted 13:07, Wednesday 21 January 2015 (16187)
Script for the sensor correction gain calculation fixed

I found a small mistake in the HAM_gain_matching_calculation script.

The Q of the GS13 model was wrong by a factor a few, causing a slight phase delay around the frequencies that matter for the sensor correction ([0.1Hz-0.4Hz]).  The overall amplitude was thus altered.

This has been fixed and committed into the SVN:

/ligo/svncommon/SeiSVN/seismic/HAM-ISI/Common/Misc/HAM_gain_matching_calculation.m

 

Here's the correct values that we have so far (I though we had done HAM2 as well, but I can't find a good set of data):

  HAM4 HAM5 HAM6
X 0.945 1.001 1.035
Y 0.929 0.991 1.027
Z 0.918 1.039 1.103

 

We still need to do HAM2&3, plus all the BSCs. Don't forget to put the ISI in high blend mode with sensor correction OFF when you want to calculate the gain.