Reports until 13:50, Wednesday 21 January 2015
H1 TCS
kiwamu.izumi@LIGO.ORG - posted 13:50, Wednesday 21 January 2015 (16189)
TCSX calibration filter was off, we switched it back on

As a part of the DRMI investigation, we checked the laser power of CO2X and found that the power had dropped by a factor of two or so a week ago. However it turned out that this was due to a calibration filter (FM2 of TCS-ITMX_CO2_LSRPWR_MTR) which had turned off at that time for some reason. We switched it back on and also edited safe.snap accordingly. The attached is a 100days trend of relevant channels. As shown, the input of the monitor channel stayed at a constant value approximately in the past month or so while the output suddenly changed a week ago, indicating that the calibration filter was taken out.