H1 ISIs Set to '750mHz' and 'Start' Blend Filters, with ISI and HPI Sensor Correction OFF for Gain Matching
J. Kissel, A. Pele

In order to gather measurement data for GND to ST1 sensor correction, I've switched all chamber's ISIs except for HAMs 4-6 to a high-frequency blend. For the HAMs this means the "750mHz" blends, and for the BSCs the "Start" filters (see attached) and turned both ISI X&Y and HEPI Z sensor correction OFF. Yesterday, worried that there still might be residual garbage from initial install in these filter banks, we've confirmed that all chambers involved have the same filters as attached.

The chambers have been set up in this fashion since 
1105975887 Jan 22 2015 15:31:11 UTC
(We blends switched by done by 15:05 UTC and 15:22 UTC in the HAMs and BSCs, respectively, but I forgot to turn OFF the sensor correction until Arnaud reminded).
Non-image files attached to this report
Comments related to this report
jeffrey.kissel@LIGO.ORG - 09:07, Thursday 22 January 2015 (16202)
BSCs and HAMs have been restored as of:
1105980152    Jan 22 2015 16:42:16 UTC    XARM Restored
1105981034    Jan 22 2015 16:56:58 UTC    YARM / BS Restored
1105981219    Jan 22 2015 17:00:03 UTC    HAM23 restored