Reports until 15:07, Thursday 22 January 2015
H1 CDS
david.barker@LIGO.ORG - posted 15:07, Thursday 22 January 2015 - last comment - 23:17, Thursday 22 January 2015(16210)
Editing the SITEMAP.adl medm screen

Reminder, if you wish to edit the site map, please do so in the /opt/rtcds/userapps/release/cds/h1/medm directory.

Please do not do it in the /opt/rtcds/lho/h1/medm directory as this breaks the symbolic link and the change does not get committed to the SVN version control repository.

Comments related to this report
rana.adhikari@LIGO.ORG - 23:17, Thursday 22 January 2015 (16223)ISC

Over the last couple days I have made a couple of housekeeping updates to the IFO_ALIGN screen:

  • Made the default step size for all of the big optics to be 0.1. This is to prevent people from accidentally breaking the lock by moving one of these optics by a couple microradians with a couple of fast clicks. Its still fine to have a default step size of 1 microrad on the little RC optics since the beam is little there and the cavities are not so sensitive to their motions.
  • Put an "&" into the argument string for the Save Aligned and Save Misaligned button for the COC. We can also do this for the RM, IM, and OM optics once they get assimilated by the Guardian.
  • checked into SVN