Using Dave's extract from the Guardian logs since the RCG 2.9 restart to generate an exclude file. I've loaded SDF Tables for all LHO HPIs (except HAM1.) Attached is a snap of the donot monitor file; this is Dave's file with filter module core names removed (Guardian uses ezca which doesn't have to use a complete name to manipulate a switch) and the HPI MASTER_SWITCH added (the SEI Manager toggles this switch, not the HPI Guardian.) Also in the image is the difference table from the SDF before the donot_monitor list was added. After updating the Table, the diff list went to zero channels.
All HAM HPI currently have no diffs--let's keep it that way. The BSC HPIs have a few diffs (1-4,) these are a few ISC settings and sensor correction gains that need to be corrected by updating the safe.snap value. Fab tool!
Thanks to Dave & Jonathan.
All HEPI safe.snaps and exclude lists are committed to the svn from /opt/rtcds/userapps/release/hpi/h1/burtfiles