SDF Control for LHO HPI Platforms

Using Dave's extract from the Guardian logs since the RCG 2.9 restart to generate an exclude file.  I've loaded SDF Tables for all LHO HPIs (except HAM1.)  Attached is a snap of the donot monitor file; this is Dave's file with filter module core names removed (Guardian uses ezca which doesn't have to use a complete name to manipulate a switch) and the HPI MASTER_SWITCH added (the SEI Manager toggles this switch, not the HPI Guardian.)  Also in the image is the difference table from the SDF before the donot_monitor list was added.  After updating the Table, the diff list went to zero channels.

All HAM HPI currently have no diffs--let's keep it that way.  The BSC HPIs have a few diffs (1-4,) these are a few ISC settings and sensor correction gains that need to be corrected by updating the safe.snap value.  Fab tool!

Thanks to Dave & Jonathan.

Images attached to this report
Comments related to this report
hugh.radkins@LIGO.ORG - 18:12, Thursday 22 January 2015 (16219)

All HEPI safe.snaps and exclude lists are committed to the svn from /opt/rtcds/userapps/release/hpi/h1/burtfiles