sheila.dwyer@LIGO.ORG - posted 19:46, Thursday 22 January 2015 - last comment - 13:06, Friday 23 January 2015(16220)
TR CARM work today

Evan, Alexa, Elli, Sheila, Rana,

We think that we are loosing lock due to some 12-15 Hz noise in CARM which is non stationary.   We watched the spectrum of CARM locked on ALS with and without DIFF locked, and saw that the non stationary noise is only there when DIFF is locked.  We then looked back at our ALS DIFF design (alog 15025) and decided to reduce the gain by 35%. This has reduced the gain peaking, but we still have nonstationary noise in CARM.  

lock loss times: 1:44:20 UTC, 3:01:27 UTC Jan 23rd UTC lock loss durring swept sine excitation 3:55 UTC

Comments related to this report
alexan.staley@LIGO.ORG - 19:50, Thursday 22 January 2015 (16222)

The first attachment is of a REFLBIAS transfer function when we had partially transitioned between TRXY and ALS COMM (CMB IN1 Gain was 4, and CMB IN2 gain was -11). When we measured this TF we had not engaged the FM5 boost. Still, this does not look correct ... 

The second attachment is of ALS DIFF and CARM spectra. It seems we had some gain peaking in ALS diff, which motivated us to lower the gain as Sheila mentioned. This reduced the peak in CARM, but did not eliminate it. 

Images attached to this comment
eleanor.king@LIGO.ORG - 11:37, Friday 23 January 2015 (16232)

Here are some more lock loss times for last night:

23/1/15 00:03:03 UTC

23/1/15 01:14:01 UTC

23/1/15 01:43:45 UTC

23/1/15 02:17:01 UTC

Attached is lockloss plot at 23/1/15 00:03:03 UTC.  LSC-REFL_SERVO_IN2GAIN was turned down at 00:03:03 -26 seconds.  Lock was lost 26 seconds later.  CARM noise dropped once the gain was turned down.   Also attached is a power spectrum of CARM signals before and after turning down the gain.  REfs 0 and 1 are before, refs 4 and 5 are after.  Puzzlingly, the high frequency noise increased after the ALS gain was turned down.

Images attached to this comment
Non-image files attached to this comment
sheila.dwyer@LIGO.ORG - 13:06, Friday 23 January 2015 (16235)

 Here are some other lock loss plots from yesterday.  The first one shows that the ALS Y glitch caused one of our locklosses, the Y arm transmission went to 0, with the charachteristic glitch in Y REFL CNTRL, as seen in alog 15242 and 15402.  We think this was bad luck, and a reminder that these glitches are a problem. 

The other lock losses were less conclusive so far, I've attached a plot that shows that as the gain of the ALS path is ramped down on the common mode board we have large glitches in CARM, however the lock survives this and drops a few seconds later. 

Images attached to this comment