evan.hall@LIGO.ORG - posted 19:38, Saturday 24 January 2015 - last comment - 14:02, Monday 26 January 2015(16250)
X arm lock with sqrt(TRX)

Elli, Sheila, Alexa, Rana, Evan

Since we haven't been able to reliably transition ALS COMM to sqrt(TRX+TRY), we decided we'd back off a bit and try the transition with a single arm only (i.e., no DRMI).

The sequence that we found worked for us is as follows:

For most of this process we had a GPIB-controlled SR785 hooked up to the common mode and summing node boards in order to monitor the relative strengths of the ALS COMM and sqrt(TRX) signals. For the excitation we drove EXC A on the common-mode board; for ALS COMM we monitored TEST1 on SUM A, and for sqrt(TRX) we monitored TEST2 on SUM A. This was incredibly helpful for sorting out how to properly shape sqrt(TRX) and how to engineer a stable crossover during the transition.

Comments related to this report
evan.hall@LIGO.ORG - 14:02, Monday 26 January 2015 (16275)

And if anyone is looking for the freshest copy of the 40m GPIB scripts, they are maintained by Eric Quintero on github: https://github.com/e-q/netgpibdata