Reports until 13:27, Wednesday 28 January 2015
H1 ISC
jim.warner@LIGO.ORG - posted 13:27, Wednesday 28 January 2015 - last comment - 13:39, Thursday 29 January 2015(16327)
Pop 18 trend showing window for last nights lock

Looks like lock was from about 9:14 UTC to 16:09 UTC. For posterity.

Images attached to this report
Comments related to this report
jeffrey.kissel@LIGO.ORG - 13:39, Thursday 29 January 2015 (16349)DetChar, ISC, SEI, SUS
Also for posterity:
- This is a DRMI lock stretch.
- IMC WFS DOF4 is OFF
- No corner station WFS engaged. 
- ISS second loop is *OFF*. 
- 10 [W] input reqested. 
- SEI was in the most recent nominal configuration -- 
    HPI Pump Servo ON, 
    Sensor Correction to ISI XY and HEPI Z, 
    (no ST0-1 Feed Forward yet), 
    Using 01_28 blends on the HAM ISIs, 
    "45 [mHz]" X&Y, LLO blends on BSC ISIs.

Great for offline, data-mining studies of
- Gain Problems with STS2B
- HAM3 0.6 [Hz] feature
- Coherence with HPI Pump Pressure.
- DAC major-carry transition glitches.
- Cavity performance with respect to SEI performance.
- Lock Loss statistics

Among other things...