kiwamu.izumi@LIGO.ORG - posted 11:12, Thursday 29 January 2015 - last comment - 11:26, Thursday 29 January 2015(16340)
some maintenance in initial alignment

Ed and Kiwamu,

In the morning of today and yesterday, we went through all the initial aligment steps. In the course of the process, we found that there were a few settings that were hidden and not set correctly. So we made a couplle of modifications on the guardians and filter in order to automate them:

The attached screenshot shows the current good settings in order to go through the alignment sequence. This configuration should be automatically achieved by the guardians.

Images attached to this report
Comments related to this report
kiwamu.izumi@LIGO.ORG - 11:26, Thursday 29 January 2015 (16341)

Some additional notes:

We found two failure modes which we did not get a chance to fix the guardians. I will have a close look at them tomorrow morning or next week.

  • ISC_DRMI for some reason did not set the PSL power back to the nominal of 10 W even though we requested the DOWN state.