Updated GUARD_OVERVIEW and IM/TT medm screens

I updated the GUARD_OVERVIEW and the IM/TT medm screens to contain micro/mini Guardians for IM1, IM2, IM3, IM4, RM1, RM2, OM1, OM2, OM3. The scripts were already made available by Stuart Aston and Jameson Rollins at LLO see https://alog.ligo-la.caltech.edu/aLOG/index.php?callRep=15772 and also https://alog.ligo-la.caltech.edu/aLOG/index.php?callRep=15585. The Guardian Nodes were not yet created though so I had to create those and figure out that they also had to be started.

Currently RM1, RM2, OM1, OM2, OM3 do not have any offset.snap files saved to them in userapps/sus/h1/burtfiles/ (hence the red border on the Guardian Minis in the overview screen shot).

Attached are the before and after of the GUARD_OVERVIEW.adl screens along with the new HAUX and one of the new HSSS IM screens.

Images attached to this report
Comments related to this report
jameson.rollins@LIGO.ORG - 10:37, Monday 02 February 2015 (16411)

The red boarder actually indicates an ERROR with the node.  If there's not actualy ERROR conditions in those nodes, then there might be a version incompatibility between the version of guardian in use and the indicator screen.

I'll help resovle this issue when I'm on site tomorrow.