Displaying report 1-1 of 1.
Reports until 16:00, Monday 02 February 2015
H1 General
travis.sadecki@LIGO.ORG - posted 16:00, Monday 02 February 2015 (16417)
Morning meeting notes and OPS shift summary

Morning meeting:

SEI running TFs as target of opportunity for feedforward on all ISIs

Krishna will be here this week for BRS work at EX

HEPI pumpstation work

TJ working on RM and OM SUS Guardians

Jamie will be here this week working on Guardian

Matt Heintze will be here this week for 3IFO work

Beamtube cleaning ongoing

Bubba working on 3IFO purge plumbing in LVEA

 

OPS Shift Summary:

6:30 Cris and Karen to LVEA

8:19 Karen to EY, Cris to EX

8:23 Ken working on air handlers at EX and EY

8:50 Corey to squeezer bay

8:51 Ken to EY

8:51 Bubba to LVEA H2 input area

9:05 Corey done

9:19 Jodi to mid stations

9:23 Karen done

9:33 JeffK, Krishna, and Hugh to HEPI pumpstation

9:40 Jodi back

10:06 JeffK, Krishna, and Hugh done

12:00 Ken to EX HVAC work

13:48 Ken done at EX

13:54 Fil to MY for parts hunt

14:24 Fil done
 

I locked both arms with green this morning, and attempted to lock DRMI, but was foiled due to sneaky filter settings and constantly changing methodology (unable to follow OPS instructions due to changes by commissioners).