Displaying report 1-1 of 1.
Reports until 01:17, Tuesday 03 February 2015
H1 ISC
sheila.dwyer@LIGO.ORG - posted 01:17, Tuesday 03 February 2015 - last comment - 11:04, Tuesday 03 February 2015(16424)
today's locking progress
Alexa, Evan, Sheila, Kiwamu, Elli, Daniel
 
Today we made several small improvements

We then made several attempts to transition off of TR_CARM.  As on friday, we are able to get to low CARM offsets, and sit there stably, but haven't been able to turn off TR_CARM yet.  We found that we could sit at about 5 pm (TR CARM = -39) stably with just TR_CARM on. 

Transition attempts:

At -36 in TR_CARM, engage analog REFLAIR 9 with 40 dB total gain on summing junction and CM board. 

At -36. engage REFLAIR9 with and offset of -1.8, tried turning off FM 9 (the complex pole compensation) in TR_CARM.  Lost lock at 7:23:45

We've had trouble engaging the DHARD WFS with the opposite sign at the small CARM offsets tonight, which on Friday seemed like it was key to being stable at low offsets.  

Comments related to this report
alexan.staley@LIGO.ORG - 11:04, Tuesday 03 February 2015 (16431)

At one point we also tried transitioning at a farther offset. If I remember correcly, the CARM offset was about -25. This also failed.

Displaying report 1-1 of 1.