Reports until 16:13, Tuesday 03 February 2015
H1 SEI
hugh.radkins@LIGO.ORG - posted 16:13, Tuesday 03 February 2015 (16442)
LHO Corner Station HEPI Pump Stations Maintenance

Pump #8 back on line--FClara had to rewire the db9 end of the Control VOUT.

Pump #7 taken off line to check Accumulators--all good, none with low pressures, #7 back on line.

Added explicit ground to + & - power outputs of power supply.  All kinds of wires jiggled, poked, & twisted.  No change in the sensor noise.