locking today

Evan, Alexa, Lisa, Ryan, Sheila

Today we were able to lock about 7 more times todat, for at most a half hour.

We have many examples of locklosses from today.  We have added lock loss states to the guardians, so we should be able to get a list of these off the Detchar summary pages or the command line utility.  

Images attached to this report
Non-image files attached to this report
Comments related to this report
daniel.sigg@LIGO.ORG - 08:12, Monday 09 February 2015 (16570)

The inability to zero AS_I tends to be an inidcation of unequal RF sidebands, either in amplitude or shape. This is generally caused by the Schnupp asymmetry togther with a differential short Michelson effect such as a differential thermal lens or to a lesser degree ITM alignment and dark fringe offsets.