filiberto.clara@LIGO.ORG - posted 16:21, Wednesday 11 February 2015 (16664)
TCS AA Chassis Repair
This morning Dave and Alastair reported one of the TCS AA chassis in the CER was found powered off. Switched unit back on and found the -15V led was flickering. Took chassis S1300387 to lab and found two buffer IC's (AD8622) had had failed on board S1300387 on CH3 and CH4. Replaced IC's and ran transfer functions. Unit was replaced back in rack.